Application of a semi-micro method to routine monitoring of chemical oxygen demand (COD) of sugar factory effluents
Code (CO)MSI99P1452
Author (AU)Wong Sak Hoi, L.
Title - English (ET)Application of a semi-micro method to routine monitoring of chemical oxygen demand (COD) of sugar factory effluents
Document Type(DT)Periodical article
Date of publication (DP)1992
Series (SE)Revue agric. sucr. Ile Maurice
Source (SO)71 (2 / 3): 339-349
Notes (NO)Published 1993
Language of text (LT)En
Language of summaries (LS)En
Fr
Abstract (AB)A semi-micro chemical oxygen demand (COD) apparatus offering the alternatives of colorimetric and titrimetric methods of estimating COD, after sample digestion in custom-prepared vials, was evaluated against the standard macro method as reference. Reagent mixture for digestion was prepared in the laboratory and the corresponding colorimetric and titrimetric methods were developed, and subsequently evaluated against the reference method. All methods were found comparable in precision and acuracy. It is proposed to dilute all effluent samples to less than150 mg/L COD prior to digestion in laboratory-prepared reagents followed by colorimetric estimation. The method provides an inexpensive, simple and rapid pollution control tool for day-to-day monitoring of sugar factory effluents.
Descriptors - English (DE)SUGAR FACTORY WASTES
CHEMICAL OXYGEN DEMAND
SUGAR
PROCESSING
Descriptors - Geographic (DG)MAURITIUS
Sort Key 1(K1)Sugar processing
Date record entered (DA)1993-01-08
Language of analysis (LA)En
Location (LO)LIB
Processing status (PS)CAT
MSIRI Staff (MS)ST